Views: 4 Author: Site Editor Publish Time: 2022-12-05 Origin: Site
Whether high-pressure water gun can be used to clean Atlas cooler is affirmative. The following cleaning methods for the air compressor cooler are summarized below for reference only.
Cleaning steps for the air compressor cooler: close the main control valve of the air compressor, open the air compressor drain valve, open the oil cut-off valve, and drain the oil. Precautions: When starting the oil discharge, open the pipeline to completely drain the oil and prevent oil leakage.
The reason for some dirt generated by the air compressor cooler is that after long-term use, calcium, magnesium and other bicarbonate substances in the air compressor cooler water will develop and form scale, causing the temperature of the air compressor inlet and exhaust system to continuously increase, and the air quality cannot be cooled to the predetermined temperature. Therefore, it is very important for us to clean the air compressor cooler.
The specific cleaning steps and methods of Atlas cooler are as follows: when the air compressor equipment stops and the pressure is confirmed to be released, pull down the main power switch. Open the air guide cover to clean the cover, or remove the cooling fan. Clean the dirt on the guide cover with compressed air and spray some degreasing agent. When the air compressor cooler cannot be cleaned using the above method, it should be soaked or sprayed with cleaning solution, cleaned with a brush, and then installed with a cover plate or cooling fan.
Stop the operation and confirm that the pressure has been released. Pull down the main power switch, disconnect the cooling water inlet and outlet pipes, soak them in cleaning solution or rinse them with a pump, or rinse them with water. Install the cooling water inlet and outlet pipes, and the water-cooled unit can be directly immersed for cleaning. The water can be circulated through a circulating pump.
Before maintenance, stop the air compressor, press the emergency stop button, and cut off the power supply. All relevant measures must be carried out by the operator. Keep the cooler unit clean to maintain cooling efficiency. For air-cooled air compressors, please perform the following operations: unscrew the bolts, rotate the fan, and separate it from the cooler unit; Blow the air from the head chamber of the air compressor through the cooler to the drive motor chamber. Return the fan to its original position and secure it to ensure that it can rotate freely.
For water-cooled units, please consult the after-sales personnel of the air compressor. When handling Atlas cooler, please pay special attention to the following measures and do not inhale refrigerant vapor. Please check if the work area is well ventilated, and if necessary, use certain equipment and machinery. Be sure to wear special gloves. If the refrigerant comes into contact with the skin, immediately rinse the skin with water. If liquid refrigerant comes into contact with skin through clothing, do not hastily remove clothing. On the contrary, rinse the clothes with a large amount of water until all the mixture disappears, and then seek assistance. Protect your hands from touching hot machine parts, such as when draining oil.